Share:


LEDVANCE ELEMENT 120W 220-240V 24V GEN2 - 120/220-240/24 G2

LEDVANCE ELEMENT 120W 220-240V 24V GEN2 - 120/220-240/24 G2

  • 120/220-240/24 G2

Product family features
  • Linear form factor
  • Power factor: >0.95 at full load
  • Total Harmonic Distortion (THD): < 15%
  • Output voltage tolerance: < 3%
  • Up to 30,000 h @ Tc max / up to 50,000 h @ Tc -10 °C
  • Lifetime: up to 30,000 h (temperature at max. tc )

Product family benefits
  • High efficiency (up to 91 %)
  • Higher quality of light thanks to < 3% output ripple current
  • Excellent price/performance ratio
  • Class II design for wide application
  • 3 years guarantee

Areas of application
  • Decorative lighting in hospitality, restaurants and Shops
  • Shelf lighting
  • Cove lighting
  • Under cabinet lighting

Electrical data
  • Nominal input voltage : 220…240 V
  • Mains frequency : 50…60 Hz
  • Input voltage AC : 198…264 V
  • Power factor λ : 0.95
  • Efficiency in full-load : 89 % 1)
  • Device power loss : 14.8 W 2)
  • Inrush current : < 32 A 3)
  • Max. ECG no. on circuit breaker 10 A (B) : 5
  • Max. ECG no. on circuit breaker 10 A (C) : 8
  • Max. ECG no. on circuit breaker 16 A (B) : 8
  • Max. ECG no. on circuit breaker 16 A (C) : 12
  • Max. ECG no. on circuit breaker 25 A (B) : 12
  • Surge capability (L-N) : 1 kV
  • Nominal output voltage : 24 V
  • Nominal output power : 120 W
  • Maximum output power : 120 W 4)
  • Galvanic isolation primary/secondary : 3 kV
  • Output ripple Voltage (100 Hz) : < 3 %
  1.  at 230 V, 50 Hz
  2.  At Full load, 230 V, 50 Hz
  3.  At 520 μs
  4.  at steady state

Dimensions & weight
  • Mounting hole spacing, length : 252 mm
  • Product weight : 386.00 g
  • Cable cross-section, input side : 0.75…1.5 mm²
  • Cable cross-section, output side : 0.75…1.5 mm²
  • Wire preparation length, input side : 5.0 mm
  • Length : 260.0 mm
  • Width : 40.0 mm
  • Height : 31.0 mm

Colors & materials
  • Casing material : Plastic

Temperatures & operating conditions
  • Ambient temperature range : -20…+50 °C
  • Maximum temperature at tc test point : 90 °C
  • Max.housing temperature in case of fault : 110 °C
  • Temperature range at storage : -40…+85 °C
  • Permitted rel. humidity during operation : 5…85 % 1)
  1.  Non-condensing

Lifespan
  • ECG lifetime : 30000 h 1)
  1.  At maximum Tc / 10% failure rate

Additional product data
  • Predecessor EAN : 4052899528703, 4052899463813

Capabilities
  • Dimmable : No
  • Overheating protection : Yes
  • Overload protection : Yes
  • Short-circuit protection : Yes
  • Intended for no-load operation : No
  • Suitable for fixtures with prot. class : I / II
  • Number of channels : 1

Certificates & standards
  • Approval marks – approval : CE / RCM / CCC / MM
  • Standards : Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to / IEC 62384/Acc. to IEC 61000-3-2/Acc. to CISPR / 15/Acc. to IEC 61000-3-3/Acc. to IEC 61547
  • Type of protection : IP20

Specifications

Sorry, currently do not have any product specifications
Sorry, currently do not have any video uploaded.