Share:


MEANWELL 60W SINGLE OUTPUT SWITCHING POWER SUPPLY - LPV-60 SERIES - LPV-60-12

MEANWELL 60W SINGLE OUTPUT SWITCHING POWER SUPPLY - LPV-60 SERIES - LPV-60-12

  • LPV-60-12

Features
  • Constant voltage design
  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Over load / Over voltage
  • Cooling by free air convection
  • Fully encapsulated with IP67 level
  • Fully isolated plastic area
  • Class II power unit, no FG
  • Class 2 power unit
  • Pass LPS
  • Suitable for LED related fixture or appliance (such as LED Decorations or Advertisement devices)
  • 100% full load burn-in test
  • Low cost, high reliabaility
  • 2 years warranty
GTIN CODE

SPECIFICATION
  • Model : LPV-60-12
Output 
  • DC voltage : 12V
  • Rated current : 5A
  • Current accuracy : 0~5A
  • Rated power : 40W
  • Ripple & noise : 120mVp-p
  • Voltage tolerance : ±5.0%
  • Line regulation : ±1.0%
  • Load regulation : ±2.0%
  • Setup, Rise time : 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
  • Hold up time : 50ms/230VAC 16ms/115VAC at full load
Input
  • Voltage range : 90 ~ 264VAC 127 ~ 370VDC
  • Frequency range : 47 ~ 63Hz
  • EFFICIENCY (Typ.) : 83%
  • AC current : 12V : 1.2A/115VAC 1A/230VAC
  • Inrush current : COLD START 60A(twidth=525μs measured at 50% Ipeak) at 230VAC
  • Max. No. of PSUs on 16A Circuit breaker : 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
  • Leakage current : 0.25mA / 240VAC
Protection
  • Over load : 110 ~ 150% rated output power / Protection type : Hiccup mode, recovers automatically after fault condition is removed
  • Over voltage : 13.8 ~ 16.2V / Protection type : Shut down o/p voltage, re-power on to recover
Environment
  • Working temp. : -30 ~ +70℃ (Refer to ''Derating Curve'')
  • Working humidity : 20 ~ 90% RH non-condensing
  • Storage temp. humidity : -40 ~ +80℃, 10 ~ 95% RH
  • Temp. coefficient : ±0.03%/℃ (0 ~ 50℃)
  • Vibration : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety & EMC
  • Safety standards :  UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(for LPV-60-12,LPV-60-24 only), EAC TP TC 004, IP67, IEC62368-1 , BS EN/EN62368-1 approved
  • Withstand voltage : I/P-O/P:3KVAC
  • Isolation resistance : I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
  • EMC emission : Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020
  • EMC immunity : Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
Others
  • MTBF : 5188.4K hrs min. Telcordia SR-332 (Bellcore) ; 732.1Khrs min. MIL-HDBK-217F (25℃)
  • Dimension : 162.5*42.5*32mm (L*W*H)
  • Packing : 0.4Kg; 32pcs/13.8Kg/0.63CUFT

Specifications