JM Recess Emergency Keluar Sign - TR218C/R [SIRIM]
Brand: BSLIGHT
Category:
EMERGENCY KELUAR SIGN
View Details
Quantity: In Stock
Selected variant:
JM Recess Emergency Keluar Sign - TR218C/R [SIRIM]
Selected variant:
JM Recess Emergency Keluar Sign TR218C/R SIRIM BOMBA
The JM Recess Emergency Keluar Sign TR218C/R is a commercial-grade, flush-mounted emergency exit light certified by SIRIM and BOMBA (MS 983:2004, MS 619-2-22:2012, MS IEC 60598-1:2012). Built with energy-efficient SMD LEDs, a heavy-duty powder-coated metal housing, and a 3-hour backup Ni-Cad battery, it ensures full compliance with Malaysia’s Uniform Building By-Laws (UBBL) for offices, retail spaces, and industrial projects.
Full Description:
Ensure Fire Safety & UBBL Compliance in Malaysia
When fitting out commercial offices, industrial complexes, or retail lots, regulatory approval is mandatory. The JM Recess Emergency Keluar Sign (Model: TR218C/R) provides clean, semi-recessed aesthetic integration while fulfilling strict Malaysian fire and building safety mandates. Certified with full SIRIM licensing and BOMBA Fire Department approval, this emergency sign guarantees smooth site inspections and long-term emergency reliability.
High-Efficiency LED Technology & Maintained Operation
Operating in Maintained Mode (continuously lit during normal power supply and automatically sustained during power outages), the TR218C/R utilizes 16 x 0.2W high-grade SMD LEDs. This design delivers clear, uniform light output across the sign with minimal energy consumption (less than 6.3VA). Whether running under standard 240V mains power or switching seamlessly to battery supply during a blackout, visual guidance remains crisp and visible.Advanced Battery Protection & Reliable 3-Hour Backup
Equipped with a high-temperature Sealed Nickel-Cadmium (Ni-Cad) Battery, the unit provides over 3 hours of continuous emergency operation, exceeding the statutory minimum requirement.-
Built-in Low Voltage Cut-Off: Protects the internal battery pack from deep discharge damage during prolonged power outages.
-
Integrated LED Indicator: A clear Red LED charging monitor allows facility managers to verify battery charging status at a glance.
Sleek Semi-Recessed Metal Architecture
Unlike bulky surface-mounted exit boxes, the TR218C/R features a flush recessed design where the power module and housing fit cleanly into plaster ceilings or wall cut-outs, leaving only the illuminated face panel visible for a modern architectural look. The body is constructed from durable metal finished in a corrosion-resistant epoxy powder coating, designed for an IP20 protection rating.Specifications
- Model: TR218C/R
- Mode of Operation: Maintained
- Input Voltage: 240V±10% 50Hz
- Power Consumption: <6.3VA
- Battery Type: Sealed Nickel-Cadmium Battery
- Lamp Used: SMD LED
- Lamp-Mains ''ON'': 16 × 0.2W SMD LED
- Lamp-Main ''OFF'': 16 × 0.2W SMD LED
- Rated Duration:>3 Hours
- Housing: Metal Casing Finish in Epoxy Powder Coating
- Changing Monitor: Red LED Indicates Battery Charging
- Projection Rating: IP20
- Safety Feature: Low Voltage Cut-off to Prevent Over Discharge of the Battery
- Mounting Type: Wall or Ceiling Mounting
- Certified Compliance: MS983:2004 , MS619-2-22:2012 , MS IEC 60598-1:2012 , BOMBA APPROVED
- Dimension Keluar: 538(L)mm × 198(W)mm × 125(H)mm
- Keluar Recess: D1- 540(L)mm × 40(W)mm × 55(H)mm , D2 - 620(L)mm × 82(W)mm
- Outer Box: 640(L)mm × 43(W)mm × 22(H)mm
- Inner Box: 625(L)mm × 205(W)mm × 82(H)mm
Q1: Is the JM TR218C/R Keluar Sign BOMBA and SIRIM approved in Malaysia?
A:Yes, the JM TR218C/R is fully certified with SIRIM licensing and BOMBA Fire Department approval. It fully complies with Malaysian Standards MS 983:2004, MS 619-2-22:2012, and MS IEC 60598-1:2012 for legal commercial building usage under Malaysian UBBL guidelines.
Q2: What is the difference between TR218C and TR218C/R?
A:The standard TR218C is a surface-mounted exit sign, whereas the TR218C/R is a semi-recessed model designed to conceal its main housing inside wall or plaster ceiling cut-outs for a sleeker architectural look.
Q3: How long does the battery backup last on the JM TR218C/R during a blackout?
A:It features a high-temperature Sealed Nickel-Cadmium battery that provides a certified backup duration of more than 3 hours during power failures。
Q4: What does "Maintained Mode" mean for an emergency exit light?
A:Maintained mode means the sign stays illuminated continuously during normal operating hours via mains power and seamlessly switches to internal battery power during a blackout.
Q5: How do I know if the battery in the JM TR218C/R is charging properly?
A:The unit features an integrated Red LED indicator on the body that lights up continuously to show the battery is receiving charge from the 240V mains supply.
Q6: What safety features prevent the battery from burning out or draining completely?
A:The unit includes a built-in Low Voltage Cut-Off circuit that automatically disconnects the load when battery levels drop too low, preventing deep discharge and extending overall battery life.
Q7: What cut-out size is needed for installing the JM TR218C/R recessed exit sign?
A:The recessed base body (D1) measures 540mm (L) × 40mm (W) × 55mm (H), while the outer trim frame (D2) measures 620mm (L) × 82mm (W) to cover the cut-out edges.
Q8: Where should a recessed Keluar sign be installed?
A:Recessed Keluar signs are ideal for plaster ceiling or dry-wall installations in offices, hotels, shopping malls, corridors, and public buildings where a clean, minimal appearance is preferred over surface-mounted boxes.
Q9: Can this emergency sign withstand outdoor weather conditions?
A:No, the JM TR218C/R has an IP20 ingress protection rating, meaning it is designed strictly for indoor use or weather-protected indoor spaces.
.png)
.png)
.png)
.png)
.png)
A:Yes, the JM TR218C/R is fully certified with SIRIM licensing and BOMBA Fire Department approval. It fully complies with Malaysian Standards MS 983:2004, MS 619-2-22:2012, and MS IEC 60598-1:2012 for legal commercial building usage under Malaysian UBBL guidelines.
Q2: What is the difference between TR218C and TR218C/R?
A:The standard TR218C is a surface-mounted exit sign, whereas the TR218C/R is a semi-recessed model designed to conceal its main housing inside wall or plaster ceiling cut-outs for a sleeker architectural look.
Q3: How long does the battery backup last on the JM TR218C/R during a blackout?
A:It features a high-temperature Sealed Nickel-Cadmium battery that provides a certified backup duration of more than 3 hours during power failures。
Q4: What does "Maintained Mode" mean for an emergency exit light?
A:Maintained mode means the sign stays illuminated continuously during normal operating hours via mains power and seamlessly switches to internal battery power during a blackout.
Q5: How do I know if the battery in the JM TR218C/R is charging properly?
A:The unit features an integrated Red LED indicator on the body that lights up continuously to show the battery is receiving charge from the 240V mains supply.
Q6: What safety features prevent the battery from burning out or draining completely?
A:The unit includes a built-in Low Voltage Cut-Off circuit that automatically disconnects the load when battery levels drop too low, preventing deep discharge and extending overall battery life.
Q7: What cut-out size is needed for installing the JM TR218C/R recessed exit sign?
A:The recessed base body (D1) measures 540mm (L) × 40mm (W) × 55mm (H), while the outer trim frame (D2) measures 620mm (L) × 82mm (W) to cover the cut-out edges.
Q8: Where should a recessed Keluar sign be installed?
A:Recessed Keluar signs are ideal for plaster ceiling or dry-wall installations in offices, hotels, shopping malls, corridors, and public buildings where a clean, minimal appearance is preferred over surface-mounted boxes.
Q9: Can this emergency sign withstand outdoor weather conditions?
A:No, the JM TR218C/R has an IP20 ingress protection rating, meaning it is designed strictly for indoor use or weather-protected indoor spaces.
.png)
.png)
.png)
.png)
.png)
Specifications
Sorry, currently do not have any video uploaded.