Share:


AURORE RLT 10/60A 415V Digital KWH Meter (DTS-238)

RLT DTS-238 3 Phase Digital kWh Meter 10/60A 415V

The AURORE RLT DTS-238 is a Class 1 precision, three-phase 4-wire electronic digital kWh meter engineered for 3x240/415V AC 50Hz industrial and commercial power distribution networks. Manufactured in compliance with international standards IEC 62053-21 and IEC 62052-11, this direct-type sub-meter supports current loads from 10A up to 60A. It provides a reliable, tamper-resistant active energy monitoring solution for factories, shop lots, commercial plazas, office buildings, and multi-tenant rental properties across Malaysia.

Full Description:

The AURORE RLT DTS-238 Three Phase Electronic kWh Meter delivers precise active energy sub-metering for commercial and industrial facilities running on standard 3-phase 415V electrical infrastructure in Malaysia. Integrating advanced digital microelectronics, microprocessing units, and high-precision digital sampling technology, this direct-connected kWh meter records active kilowatt-hour consumption reliably across all three live phases and neutral lines.
 

High-Precision Energy Monitoring & Industrial Reliability

Engineered for strict energy billing and power audits, the RLT DTS-238 maintains Class 1 measurement accuracy, keeping baseline measurement tolerance within ±1.0%. With a base current rating of 10A and a maximum continuous current throughput of 60A (10/60A), the unit handles varying electrical loads across commercial distribution panels without thermal degradation or accuracy loss. Its clear digital LCD display replaces prone-to-wear mechanical registers, eliminating reading human error and enabling property managers, wiremen, and facility engineers to capture billing readings quickly.  
 

International Compliance & Built-In Safety Architecture

The AURORE RLT DTS-238 complies fully with key international electricity metering standards:
  • IEC 62053-21: Regulates static meters for AC active energy (Class 1 accuracy standard).
  • IEC 62052-11: Establishes general requirements, testing criteria, and environmental resilience for electricity metering equipment.

Commercial Applications in Malaysia

  • Rental Sub-Metering: Ideal for landlords and commercial building owners allocating exact electricity costs to individual tenants in shared shop lots, shopping malls, and industrial parks.
  • Industrial Facilities: Monitors heavy machinery, production lines, HVAC units, and heavy 3-phase equipment usage for energy-saving audits.
  • Property Management: Simplifies sub-meter installation inside indoor main switchboards (MSB) or outdoor distribution boxes (DB) behind main utility power meters.

Installation Guidelines

The DTS-238 utilizes a straightforward 4-wire direct connection layout. Electrical contractors should confirm correct phase sequence (Phase A/B/C) and tight neutral terminal connections inside the distribution board. Installation must be conducted by a certified wireman or electrical engineer registered with Suruhanjaya Tenaga (ST Malaysia) to ensure safety and code compliance.  
 
Specifications
  • Brand: RLT
  • Model: DTS-238
  • Product Type: Three Phase Electronic kWh Meter
  • Voltage: 3×240/415V 50Hz
  • Current: 10/60A
  • Accuracy Class: Class 1
  • Standard: IEC62053-21 ,  IEC62052-11

Q1: What is the AURORE RLT DTS-238 3-phase digital kWh meter used for in Malaysia?
A:The AURORE RLT DTS-238 is a 3-phase electronic electricity sub-meter used to measure kilowatt-hour (kWh) power consumption in 415V commercial, industrial, and multi-tenant rental properties across Malaysia.

Q2: What does the 10/60A rating mean on the RLT DTS-238 meter?
A: "10/60A" indicates a base operating current of 10 Amperes and a maximum continuous current load capacity of 60 Amperes per phase without compromising meter accuracy or safety.

Q3: Can I use the RLT DTS-238 as a sub-meter for tenant utility billing?
A: Yes, property owners in Malaysia widely use the RLT DTS-238 as a private sub-meter to track and calculate individual utility bills for rented commercial shop lots, offices, and industrial factory units.

Q4: What is Class 1 accuracy in a 3-phase digital energy meter?
A: Class 1 accuracy means the energy meter operates with a maximum allowable error margin of ±1.0% under standard load conditions, ensuring highly reliable billing data.

Q5: What international standards does the RLT DTS-238 comply with?
A: It complies with IEC 62053-21 (for Class 1 static AC active energy meters) and IEC 62052-11 (for general electricity metering requirements and environmental testing).

Q6: Can the AURORE RLT DTS-238 sub-meter replace an official TNB main meter?
A: No, official grid connections require meters supplied directly by Tenaga Nasional Berhad (TNB). The RLT DTS-238 is intended for internal sub-metering and private power monitoring after the main TNB supply board.

Q7: Why choose a digital kWh meter over a traditional mechanical disk meter?
A: Digital kWh meters provide higher accuracy, prevent mechanical wear and tear, resist tampering, and offer instant, error-free LCD readings.

Specifications

Sorry, currently do not have any product specifications
Sorry, currently do not have any video uploaded.